Ceramic Products
Signature Ceramic Fiber Fabric
Eight DSZCF models · up to 1760 °C · cut to your length × width
₹510.00/ SQM
Signature ceramic fiber fabric · Visakhapatnam & Anakapalli
A barrier beside a casting bay at Ukkunagaram, outage pads on a Parawada boiler and a heat-treatment wrap in an Autonagar workshop all call for ceramic cloth — but not the same build. This page matches Visakhapatnam heat-zone maintenance to the right Signature Ceramic Fiber Fabric model: metallic or non-metallic, 1.5 mm to 6.0 mm. We make it at our Ahmedabad factory, cut to your size, and dispatch to your plant.
Ceramic Products
Eight DSZCF models · up to 1760 °C · cut to your length × width
₹510.00/ SQM
Visakhapatnam's heavy industry runs from the integrated steel works at Ukkunagaram and the Autonagar estate in Gajuwaka, west to the Parawada power and pharma belt, and south into the Atchutapuram–Rambilli cluster in Anakapalli district. Each generates a different kind of high-temperature maintenance work.
Integrated steel works — Gajuwaka, south-west Visakhapatnam
Start with: DSZCF4.0 / DSZCF5.0; DSZCF6.0 for fixed barriers
APIIC engineering estate — Gajuwaka mandal
Start with: DSZCF3.0; DSZCF3.0NM around induction heating
Coal-fired super thermal power station (4 × 500 MW) — Parawada mandal
Start with: DSZCF3.0 / DSZCF3.0P
APIIC pharmaceutical SEZ — 2,143 acres, Parawada
Start with: DSZCF2.0 / DSZCF3.0
APIIC multi-product SEZ and industrial parks — Anakapalli district
Start with: DSZCF3.0; DSZCF4.0 for barriers
Pick the row closest to your job. Each row links to the product page, where you choose the model and enter length and width, then buy online or request a quote. For an outage that needs several builds, put each on its own quotation line.
| Heat-zone job | Start with | Build | Working temperature | Order |
|---|---|---|---|---|
| Hanging heat barrier beside a furnace, ladle or casting area | DSZCF4.0 / DSZCF5.0 | 4.0–5.0 mm · 1800–2500 GSM · SS metallic reinforced | 1260 °C to 1760 °C | |
| Heaviest fixed barrier or cover that stays in place | DSZCF6.0 | 6.0 mm · 3500 GSM · SS metallic reinforced · 1 × 20 m reference roll | 1260 °C to 1760 °C | |
| Removable pads and flange or valve wraps refitted each boiler or turbine outage | DSZCF3.0 | 3.0 mm · 1000 GSM · SS metallic reinforced | 1260 °C to 1760 °C | |
| A 3.0 mm wrap that wore through too quickly last time | DSZCF3.0P | 3.0 mm · 1500 GSM · SS metallic reinforced | 1260 °C to 1760 °C | |
| Heat-treatment wrap near induction coils or live electrical equipment | DSZCF3.0NM | 3.0 mm · 1000 GSM · non-metallic ceramic cloth | 1260 °C to 1760 °C | |
| Thin, flexible wrap over small fittings and tight bends | DSZCF1.5 / DSZCF2.0 | 1.5–2.0 mm · 800–950 GSM · SS metallic reinforced | 1000 °C to 1760 °C | |
| Pad face that rubs in service, or where a sealed face is needed | DSZGCF3.0 (graphite coated) | 3.0 mm · 1000 GSM · graphite coated both sides, black | 1260 °C to 1760 °C |
Confirm the figures on the variant you select on the product page before you specify.
Send these five details with your cut list and we can quote every line in one go.
Darshan Safety Zone manufactures Signature Ceramic Fiber Fabric at our Ahmedabad factory, cuts it to the length and width on your order, and dispatches to plant addresses in Visakhapatnam and Anakapalli districts. We do not hold stock or run a branch in Andhra Pradesh. We confirm dispatch for your models and quantities on the quotation, so put the outage date on your request.
Fabric covers wraps, pads and barriers. Seals, joints and ready-made blankets are separate products.
Check the material choice and the temperature listing, or see how ceramic cloth fits a wider steel or power-plant protection programme.
Where glass cloth stops and ceramic fibre takes over, compared by temperature and use.
Open guideWhat a listed working-temperature range does and does not tell you before you specify.
Open guideHeat protection across melting, casting and rolling operations.
Open industry journeyInsulation and hot-work protection for boiler and turbine maintenance.
Open industry journeyDescribe the heat source and the outage window if you are unsure which build fits.
Open contact formComparing ceramic rope, tape and fabric? Browse ceramic products.
Answers for Visakhapatnam steel, power and boiler maintenance teams ordering Signature ceramic fiber fabric.
For barriers and covers that hang near hot metal and get knocked about, start with the heavier SS metallic reinforced builds: DSZCF4.0 (1800 GSM), DSZCF5.0 (2500 GSM) or DSZCF6.0 (3500 GSM), all listed at 1260 °C to 1760 °C. Choose by how much mass you want between the heat source and what sits behind the barrier.
DSZCF3.0 is the usual starting point for wraps and removable pads that get pulled tight and refitted: 3.0 mm, 1000 GSM, SS metallic reinforced, listed at 1260 °C to 1760 °C. If a 3.0 mm wrap has worn through too quickly in the past, specify DSZCF3.0P, which keeps 3.0 mm but goes up to 1500 GSM.
When steel in the weave is a problem: work around live electrical equipment, induction heating, or jobs where metal contamination or marking on the surface underneath is not acceptable. DSZCF3.0NM has the same 3.0 mm and 1000 GSM as DSZCF3.0, without the stainless reinforcement.
Not on the listing. DSZCF1.5 and DSZCF2.0 are rated 1000 °C to 1760 °C; DSZCF3.0 and above are rated 1260 °C to 1760 °C. If your duty sits in the 1000 °C to 1260 °C zone, specify 3.0 mm or above rather than assuming the thin cloth covers it. Confirm the figures on the variant you select on the product page.
Ceramic fiber fabric is for extreme-heat duty where glass or silica cloth is out of range — furnace and foundry wraps, barriers, pads and covers. Our fiberglass vs ceramic fiber guide compares the two by temperature and use, and the temperature-ratings guide explains how to read the listed ranges.
Use Signature Graphite Coated Ceramic Fabric (DSZGCF3.0: 3.0 mm, 1000 GSM, both sides graphite coated, listed at 1260 °C to 1760 °C) when the surface faces repeated rubbing or you need a sealed black face that sheds fewer fibres. The uncoated white DSZCF cloth suits straightforward insulation and barrier work.
It is priced by the square metre. Enter length and width in metres on the product page and the fabric is supplied cut to that size. The reference rolls — 1 × 30 m on most models and 1 × 20 m on DSZCF6.0 — are formats, not minimum orders.
No. The fabric is sold per square metre and cut to your dimensions; the ceramic fire blanket is a finished 1 × 2 m piece sold per number. The model numbers overlap but the builds differ — DSZCF4.0 fabric is 1800 GSM while the 4.0 mm blanket is 1500 GSM — so order by product page, not model number alone.
No asbestos. It is still a high-temperature mineral fibre, so cut and handle it under your site procedure for ceramic fibre materials and keep dust down. Reinforced cloth needs shears or snips rather than ordinary scissors. Before reuse, check for thinning, worn-through patches and broken steel strands, and retire worn-through material rather than patching it.
No. Darshan Safety Zone, an ISO 9001:2015 certified manufacturer, makes Signature ceramic fiber fabric at our factory in Ahmedabad, Gujarat, and dispatches to the plant address on the order. We confirm dispatch for your models and quantities on the quotation.
Send the job, DSZCF model, sizes, quantities and outage date. We will quote from our Ahmedabad factory and confirm dispatch to your plant.