Darshan Safety Zone
Back to Insightssilicon coated fiberglass cloth
Silicon FG Cloth for Weld Bays
In this article
Silicon coated fiberglass cloth is the silicone-faced roll you cut for welding curtains and equipment covers on a Selaqui fabrication bay.
You may be writing the indent for a Dehradun industrial belt weld shop, a pipe rack that needs wrap, or a stores desk that keeps coated cloth for outdoor covers through the monsoon. The cloth does not change with the pin code. Match thickness, coating side, colour, and the square metres your bay actually needs.
Jobs this cloth covers in Selaqui

You are the person who names the fabric on the requisition for a Selaqui fabrication bay or a Dehradun maintenance stores locker. Uncoated glass weave sheds fibre and takes moisture. A finished fire blanket is a cut piece sold by the unit. This indent is for roll cloth you cut to the curtain, cover, or wrap on your line.
Signature Silicon FG Cloth is woven fiberglass with a silicone rubber coating. It is sold per square metre. It is not Signature Silicon Fire Blanket, even when the model codes look related.
Put it on the workplaces this cloth is listed for.
- Welding shields, curtains, and spark barriers: bay screens and hanging faces that need a coated surface, not bare E-glass.
- Industrial heat shields and equipment covers: machine and hot-equipment covers that get refitted often.
- Pipe, duct, and expansion-joint wrap: flexible wrap on racks and joints that move with process heat.
- Reusable insulation jackets and protective covers: cut-and-sew covers that return to the same heat zone.
- Foundry, steel, and heavy engineering heat zones: short-path shields where the coated face takes sparks and hot debris better than plain weave.
Walk the duty before you raise the indent. On the Dehradun belt a cool morning outside the shed can feel mild. Inside a Selaqui weld bay or beside a hot cover, sparks and moisture still hit the cloth. Write whether the job is a hanging curtain, a pipe wrap, or an outdoor equipment cover that must shed rain after the monsoon.
If the drawing already calls for a Signature Silicon Fire Blanket (NOS, 1 × 2 m) or uncoated Signature Fiberglass Cloth, stop. Those are different SKUs. Swapping roll cloth for a blanket piece, or a blanket for SQM cloth, breaks the method.
On the indent, write the job in plain words, such as “Selaqui weld-bay curtain, silicon FG cloth by SQM”. That line stops the wrong form leaving stores.
Write the DSZSFG model on the indent

Write the model the way the catalogue lists it. Signature Silicon FG Cloth is sold per square metre under FG Product. Enter length and width in metres on the product page. Reference rolls are 1 × 50 m on most models; DSZSFG3.0 is listed on a 1 × 30 m roll.
Choose thickness, weight, coating side, and colour for the duty in front of you. Working temperature is listed per model.
- DSZSFG0.3 — 0.3 mm, 340 GSM, 550 °C to 800 °C
- DSZSFG0.4 — 0.4 mm, 460 GSM, 550 °C to 900 °C
- DSZSFG0.5 / DSZSFG0.6 — 0.5–0.6 mm, 510–560 GSM, 650 °C to 900 °C
- DSZSFG0.8 / DSZSFG1.0 — 0.8–1.0 mm, 900–970 GSM, 650 °C to 900 °C
- DSZSFG1.5 / DSZSFG2.0 / DSZSFG3.0 — thicker builds to 3 mm, 650 °C to 900 °C
- DSZSFG800 — 800 GSM build with no thickness listed on the model row; write GSM and coating side, not a guessed mm
Colour is grey, red, or black on the range. Green is listed on DSZSFG0.6 only. Coating is single side or both side — write the side your method needs. Some lighter models also list an adhesive-coating option; only tick it when the drawing asks for it.
Order cloth as cloth. Do not indent a fire blanket under this product name because the DSZSFG letters look familiar. The fire-blanket sibling is a different category, unit, and size.
Write model number, coating side, colour, and L × W in metres. A line that only says “silicon fabric Dehradun” will be guessed in stores.
Cut and check after Doon humidity

In the Doon valley, stores rooms and outdoor covers feel the monsoon. Coated cloth handles damp better than bare fiberglass, but a wet roll left open still picks up dirt and edge damage. Treat moisture and coating wear the same way — as a reason to stop and check before the next cut.
- Step 1: Match the model, coating side, and colour on the roll to the indent before anyone cuts.
- Step 2: Measure length and width in metres for the curtain, wrap, or cover. Keep the silicone face toward the spark, weather, or contact side your method names.
- Step 3: Cut cleanly. Avoid frayed edges that shed glass fibre into the bay. Finish edges the way your sewing or hanging method already uses.
- Step 4: Hang or fit the piece so it does not drag on the floor in standing water after rain. Outdoor covers on the estate need a dry fold when they come off.
- Step 5: Inspect the coating face, seams, and cut edges before every reuse. Retire a piece if the coating is cracked, peeled, or holed through to the weave.
Store rolls dry, on end or on a rack, with the model written on the bin. A cool hillside morning outside the estate does not mean the next weld window can start with an unmarked damaged remnant from last week. If a quote arrives for a silicon fire blanket under this cloth name, stop — that is a sibling SKU, not this SQM roll.
If the coated face is sticky with oil sludge or the weave shows through a worn patch, cut a fresh panel. Do not send a failed remnant back into a Selaqui spark path because “it still looks red from far away”.
Made in Ahmedabad, sent to site

Signature Silicon FG Cloth is made by Darshan Safety Zone in Ahmedabad, under the Signature brand. The company has made fire safety and heat protection products since 2012, and its quality system is certified to ISO 9001:2015.
Orders can be dispatched across India, including to a site in Dehradun, and freight is confirmed in the quotation. There is no counter in Dehradun, and there is no same-day promise.

Discussion (0)
Join the conversation
Sign in to leave a comment for our applications team.
Sign in to comment