Darshan Safety Zone

Back to Insights

Fire Proximity Suit in Haridwar

Stock Fire Proximity Suit Layers

eadmin maMarch 24, 20265 min read
Silver Signature Fire Proximity Suit ready in a plant emergency locker
In this article

An aluminized fire suit is the full-body kit you specify when a SIDCUL furnace stand-by or plant heat response puts radiant load on every side.

You may be writing the indent for a foundry locker on Haridwar’s industrial estate, a power-plant emergency bay, or a steel-line crew that still drills after the night shift. The suit does not change with the pin code. Match the radiant duty, the layer model, and the way your site issues full proximity PPE.

Stock the SIDCUL radiant stand-by kit

Worker in Signature Fire Proximity Suit beside a foundry furnace door

You are the person who stocks the emergency locker before the furnace door opens. On a SIDCUL estate in Haridwar the air outside the shed can feel mild. At the hot face, radiant heat hits the whole body. An apron or a coat will not answer that method.

Signature Fire Proximity Suit is a full aluminized proximity suit with a pure aluminium foil coated silver face. It is free size and sold per piece. It is not the aluminium coat, the back-open coat, or the aluminized apron.

Put it on the stand-by jobs this suit is listed for.

  • Foundry and furnace stand-by: close approach beside a radiant face on the estate.
  • Steel and metal-processing zones: full-body cover when heat surrounds the wearer.
  • Power-plant heat response: locker kits for outage windows and emergency drills.
  • Industrial rescue lockers: sites that stock a proximity suit instead of coat-only PPE.

Walk the duty before you raise the indent. Write whether the crew faces a furnace door, a ladle path, or a plant drill, and how long they stand in the radiant zone. A foundry night stand-by and a power-plant drill can share the same suit family and still need different layer models.

If the method already names Signature Aluminium Coat or Signature Aluminized Apron, stop. Those SKUs leave limbs or the back uncovered. Do not swap them under this suit name.

On the indent, write the job in plain words, such as “SIDCUL furnace stand-by, full suit”. That line stops the wrong garment leaving the locker.

Select layer weight for the shift

Layered silver Signature Fire Proximity Suit fabric on a stores table

Thin city pages often invent a second temperature story and a fixed 8–10 kg weight. Stay on the model row. Signature Fire Proximity Suit lists four layer builds. Colour is silver. Coating is pure aluminium foil coated. Size is free size. Working temperature on every model is 600 °C to 1000 °C.

  • DSZAL.2LS — 2 Layer, about 6 kg
  • DSZAL.3LS — 3 Layer, about 8 kg
  • DSZAL.4LS — 4 Layer, about 9 kg
  • DSZAL.5LS — 5 Layer, about 10 kg

Do not copy a brochure that stops at 900 °C, adds a separate 1200 °C radiant figure, or lists EN 469 for this SKU. Those claims are not on the current model list. Do not invent a custom cut. Approximate weight rises with layers; put that figure on the indent only as listed.

Ask the shift lead how long the wearer stands at the furnace face and how close they stand. A short inspection spell and a long stand-by are not the same duty, even on the same SIDCUL plot. Put the model number, free size, and the temperature window on the indent.

If your PPE procedure already names a layer count, copy that model. Do not drop a layer to shave a kilogram off the wearer.

Keep suit, coat, and apron apart

Full Signature Fire Proximity Suit beside a shorter aluminized apron

Haridwar lockers often hold more than one silver garment. Mixing names on the indent is how an apron leaves for a full-body stand-by. Keep the SKUs separate.

  • Proximity suit: Signature Fire Proximity Suit — full-body radiant work, models DSZAL.2LS to DSZAL.5LS.
  • Aluminium coat: a coat SKU for coat-named methods, not a suit substitute.
  • Aluminized apron: front-body torso PPE only — chest and belly, not limbs and back.

Old pages also invent a kit BOM: hood with visor, gloves, boots, and more. Those parts are not confirmed on the current model rows for this product. Write the suit model only, then complete head, hand, and foot PPE the way your site procedure already says, on their own confirmed lines.

The product is not listed as customizable. Do not add a private layer stack or a special size to the same indent. If the duty needs an apron, change the product name.

If a vendor quote lists hood, gloves, and boots as included without matching model rows, ask for the suit model alone and move extras to separate lines.

Issue, don, and retire on procedure

Plant staff donning a Signature Fire Proximity Suit before furnace stand-by

The suit only helps if the foil face looks at the heat and the locker issues the model named on the indent. Practice the sequence on a quiet drill, not on the first furnace alarm of the shift.

  • Step 1: Match the model tag to the indent before anyone puts the suit on.
  • Step 2: Don it over the base clothing your PPE procedure already names. Keep the silver foil face outward.
  • Step 3: Check free-size fit at the closures so panels sit square. A twisted panel leaves clothing bare to radiant heat.
  • Step 4: Add head, hand, and foot PPE the way the site method says, on their own confirmed lines.
  • Step 5: After the drill or first heat spell, inspect seams and foil. Retire the suit if the foil is torn, delaminated, burned through, or cracked from hard folds.

Store dry, hung or flat, with the model written on the locker. Do not patch radiant PPE with tool-crib tape. A cool morning outside the estate does not mean the next furnace window can start with an unmarked silver garment.

If the foil face is inward at issue, stop and reverse the suit before anyone steps to the hot face.

Made in Ahmedabad, sent to site

Signature Fire Proximity Suits packed for dispatch in a warehouse

Signature Fire Proximity Suit is made by Darshan Safety Zone in Ahmedabad, under the Signature brand. The company has made fire safety and heat protection products since 2012, and its quality system is certified to ISO 9001:2015.

Orders can be dispatched across India, including to a site in Haridwar, and freight is confirmed in the quotation. There is no counter in Haridwar, and there is no same-day promise.

Discussion (0)

Join the conversation

Sign in to leave a comment for our applications team.

Sign in to comment
No comments yet. Be the first to ask a specification question.

What do buyers ask before specifying?

Common questions on materials, applications, and plant fit.

When should a SIDCUL locker stock a proximity suit instead of an apron?
Stock the proximity suit when the method needs full-body cover for radiant heat. An apron only covers the front torso. Follow the name on the method before stores issues the garment.
What temperature and layer options are listed?
Every model lists 600 °C to 1000 °C. Choose DSZAL.2LS, DSZAL.3LS, DSZAL.4LS, or DSZAL.5LS. Approximate weights are 6, 8, 9, and 10 kg.
Can I claim a separate 1200 °C radiant rating or EN 469?
No. Those claims are not on the current model list. Use the working temperature on the model row. Darshan Safety Zone is ISO 9001:2015 certified as a company.
Does the suit include hood, gloves, and boots?
Those parts are not confirmed on the current model rows. Complete the ensemble per your site PPE procedure, and raise extras on separate confirmed lines.
Is the suit customizable for Haridwar plant sizes?
No. Only the four layer builds are offered at free size. Do not invent a special cut on the indent.
Do you keep stock in Haridwar for same-day issue?
No. Manufacturing is in Ahmedabad. Signature products can be dispatched across India, and freight is confirmed in the quotation. There is no local warehouse promise.
Which way should the foil face sit at the furnace door?
Keep the silver foil face outward toward the radiant source. Practice donning on a drill so the crew can check closures before the stand-by starts.
Can someone visit the plant to help pick the layer model?
Darshan Safety Zone can visit a site to recommend a product for the job. Ask for that when you request a quotation, and have the radiant duty and PPE method ready. The visit does not replace the model number on the order.

Ready to specify this for your plant?

Request a quote on welding protection, fire blankets, PPE, and high-temperature insulation — or browse the factory catalog.

Closely related products, categories, and guides to continue your specification journey.